Hartmann | Quality Assurance Program on Stereotactic Radiosurgery | Buch | 978-3-540-59199-3 | www2.sack.de

Buch, Englisch, 93 Seiten, Format (B × H): 127 mm x 190 mm, Gewicht: 114 g

Hartmann

Quality Assurance Program on Stereotactic Radiosurgery

Report from a Quality Assurance Task Group
1. Auflage 1995
ISBN: 978-3-540-59199-3
Verlag: Springer

Report from a Quality Assurance Task Group

Buch, Englisch, 93 Seiten, Format (B × H): 127 mm x 190 mm, Gewicht: 114 g

ISBN: 978-3-540-59199-3
Verlag: Springer


Radiosurgery performed with the "Gamma Knife" or on a linac facility is a specific radiotherapy method to treat certain lesions in the brain with a high single radiation dose. Geometric miss of a radiosurgica target is considered the most likely serious error in a stereotactic radiosurgery treatment. Therefore, the issue of quality assurance in stereotactic radiosurgery is a serious one for neurosurgeons, physicists, patients and those of us who wish to analyze the results of radiosurgery. The purpose of this book is to offer and describe a quality assurance program and procedures of the physical and technical aspects through identifying the sources of possible errors and suggesting quality assurance tests that should be performed in order for a stereotactic system to be used clinically.

Hartmann Quality Assurance Program on Stereotactic Radiosurgery jetzt bestellen!

Zielgruppe


Research

Weitere Infos & Material


1 Introduction.- 1.1 Purpose of the Report.- 1.2 Definition of Key Terms.- 2 Quality Assurance Aspects and Requirements.- 2.1 Quality Assurance Aspects of Stereotactic Target Localization.- 2.2 Quality Assurance Aspects of Dosimetry and Treatment Planning.- 2.3 Quality Assurance Aspects in Treatment Delivery.- 3 Description of Recommended Quality Assurance Tests.- 3.1 Stereotactic Localization and Immobilization.- 3.2 Dosimetry and Treatment Planning.- 3.3 Treatment Delivery.- 4 List of Tests.- 4.1 Stereotactic Localization and Immobilization.- 4.2 Dosimetry and Treatment Planning.- 4.3 Treatment Delivery.- Appendix A. Accuracy Requirements for Dosimetry from Tumor Control Probability Data.- Appendix B. Suggestion for Testing a Treatment Planning System.- Appendix C. Correction of Spatial Distortion in Magnetic Resonance Imaging for Stereotactic Operation/Treatment Planning in the Brain.- References.



Ihre Fragen, Wünsche oder Anmerkungen
Vorname*
Nachname*
Ihre E-Mail-Adresse*
Kundennr.
Ihre Nachricht*
Lediglich mit * gekennzeichnete Felder sind Pflichtfelder.
Wenn Sie die im Kontaktformular eingegebenen Daten durch Klick auf den nachfolgenden Button übersenden, erklären Sie sich damit einverstanden, dass wir Ihr Angaben für die Beantwortung Ihrer Anfrage verwenden. Selbstverständlich werden Ihre Daten vertraulich behandelt und nicht an Dritte weitergegeben. Sie können der Verwendung Ihrer Daten jederzeit widersprechen. Das Datenhandling bei Sack Fachmedien erklären wir Ihnen in unserer Datenschutzerklärung.